HIzlı Menü

EN FR РYC E-Tahsilat KVKK

FullPOWER VFD (1+i) 560-1310 kW

With Variable Speed Inverter Regulation (Vi inverter)
Class A High Efficiency series
Air Cooled Chillers with Axial Fan
Linear Capacity Control from 12.5% up to 100%
Eco-Friendly R134A Refrigerant

 

Eurovent Certified Outstanding Performance
High Energy Efficiency and Comfort in All Seasons
Wide and Smart Options
Increased Outdoor Air Operating Limits
Special Energy Efficient Solutions for Commercial Building

 

Quick info

Description

Technical Features
Options
Documents
Let's Call You

STRUCTURAL FEATURES

Compressor: Semi hermetic screw compressor with proportional capacity control, variable speed inverter regulation (Vi inverter) (12,5-100%), high energy efficiency, built-in thermal protection and crankcase heating.
Built-in compressor outlet line cut-off valve, limited first operation and oil level sensor.
Evaporator: Shell & tube evaporator with differential pressure switch, built-in Victaulic connection, cross flow and polyurethane insulation.
Condenser: Micro-channels condenser.
Condenser Fan: Axial fan with built-in thermal protection and protection grill.
Control: Electronic control with microprocessor.
Structure: Powder polyester painted galvanized steel structure.

STANDARD FEATURES

•High and low pressure gauges.
•Electronic expansion valve.
•Master/slave control up to parallel 4 units.
•Time-card.

VERSIONS

T - High efficiency version (TCAITZ) only cooling.
S - Super silenced version (TCAIQZ) only cooling.

FACTORY FITTED ACCESSORIES

• Single or double pump. 1 main and 1 backup applications in double pump options.
• Standard and high pressure versions of pumps are optional.
• Pump control with variable flow (VPF: Variable Primary Flow).
• Partial heat recovery option (Desuperheater).
• Full (100%) heat recovery option.
• FI-15 kit: operation at -15ºC outdoor air temperature (Condensation control) (through fans with EC motor) standard for Q version.
• Condensation control through over pressure fans.
• Power factor correction capacitor (Cosɸ>0,94).
• Compressor circuit disconnecting switch.
• Electromechanical flow switch.
• EMC electromagnetic protection filter.
• Forced power consumption limit.
• Forced noise limit.
• Energy parameters measurement device.
• Energy efficiency optimization.
• Soft starter.
• Compressor acoustical insulation.
• Compressor inlet cut-off valves.
• Refrigerant leakage detector.
• High and low pressure gauges for the refrigerant circuit.
• Double safety valves.
• Coil protection grills.
• Epoxy coated condenser with micro channels.
• Minimum/maximum power supply control.
• Digital input for double set point.
• Set point shift (4-20 mA analogue signal).
• Evaporator anti-freezing heater, electrical panel and electric pumps and heat exchangers for heat recovery if applicable.
• Interfaces for serial communication with other devices.
• Anti-vibration mouths.

SEPARATELY SUPPLIED ACCESSORIES

• Remote controller with display.
• Thermostat with display.
• Control devices for monitoring and remote management of the device.
• Sequencer for integrated management of multiple chillers.