HIzlı Menü

EN FR РYC E-Tahsilat KVKK

Compact-I MD Series 34-60 kW

Increased Outdoor Air Operating Limits
Operation at -15ºC Outdoor Air Temperature
Domestic Water Temperature up to 60ºC
Built-In Hydraulic Module

 

Plug And Play Device
EC Fans and Inverter-Controlled Circulation Pump Option
2 Piped + Heat Recovery Option (RC100)
Built-In Master/Slave Device Control

 

Quick info

Description

Technical Features
Options
Documents
Let's Call You

STRUCTURAL FEATURES

Compressor: Inverter hermetic scroll compressor with thermal protection.
Evaporator: Stainless steel plate evaporator, equipped with differential pressure switch, built-in anti-freezing heater and polyurethane insulation.
Condenser: Condenser with copper pipe/aluminium fin and protection grill.
Fan: Axial fan with built-in thermal protection and proportional speed control.
Control: Microprocessor control with the feature of Adaptive Function Plus.
Structure: Anticorrosion painted galvanized steel structure.

STANDARD FEATURES

• Outdoor air temperature sensor for set point setting.
• Electronic expansion valve.
• High and low pressure gauge.
• Master/slave control up to parallel connected 4 units.
• Time-card.

VERSIONS

T – High efficiency version, Only cooling (TCAITY) – heat pump unit (THAITY).

PUMP INSTALLATION

• Together with single or automatic shift double pump, expansion tank, manual air relief valve, safety valve and water side pressure gauges. Pump inverter options are available.

TANK AND PUMP INSTALLATION

• Together with storage tank, single or automatic shift double pump, expansion tank, manual air relief valve, safety valve and water side pressure gauges. Pump inverter options are available.

FACTORY FITTED ACCESSORIES

• Condenser with copper pipe/coated aluminium fin or copper pipe/copper fin.
• Partial heat recovery option (Desuperheater).
• Full (100%) heat recovery option.
• 3 way valve option for the domestic water.
• FI-15 kit: operation at -15 C outdoor air temperature (Condensation control) (through fans with EC motor).
• Anti-freezing heater.
• tank and pump anti-freezing heater.
• Compressor control for electricity consumption limit (digital signal).
• Refrigerant leakage detector.
• Digital input for double set point.
• Set point shift (4-20 mA analogue signal).
• Energy parameters measurement device.
• Low noise option.
• High and low pressure gauges for the refrigerant circuit.

SEPARATELY SUPPLIED ACCESSORIES

• 3 way valve option for the domestic water.
• Outdoor air temperature sensor for set point setting.
• Additional electrical heater for the heat pump.
• Water filter.
• Rubber anti-vibration mouths.
• Thermostat with display.
• Remote controller with display.
• Interfaces for serial communication with other devices.
• RS485/USB Convertor in series.
• Sequencer for integrated management of multiple chillers.