Description
STRUCTURAL FEATURES
Compressor: Hermetic scroll compressor with thermal protection and crankcase heater.
High efficiency at partial capacities through 4-6 capacity controls.
Evaporator: Plate evaporator with differential pressure switch, built-in Victaulic connection and stainless steel polyurethane insulation.
Condenser: Copper pipe/aluminium finned condenser.
Fan: Axial fan with built-in thermal protection and protective grill.
(for T version; EC fans are standard for Q versions).
Control: Microprocessor control with the feature of Adaptive Function Plus.
Carcass Structure: Powder polyester painted galvanized steel structure.
STANDARD FEATURES
• Circuit disconnecting switches of fan and compressor, anti-freezing heater for the heat exchanger.
• High and low pressure gauge.
• Electronic expansion valve.
• Time-card.
VERSIONS
T - High efficiency version, EXP systems unit (TXAETU).
Q - Super silenced version, EXP systems unit (TXAEQU).
FACTORY FITTED ACCESSORIES
- Shell & tube evaporators.
- Single or double pump. 1 main and 1 backup applications in double pump options.
- Standard and high pressure versions of pumps are optional.
- Tank and Pump Unit: Accumulation tank up to 700-1000 litres depending on the model, with expansion tank, manual air relief valve, safety valve and water side pressure gauge. Low or high pressure versions of those pumps are available.
- Partial heat recovery option (Desuperheater).
- FI-15 kit: operation at -15 C outdoor air temperature (Condensation control) (through fans with EC motor) (standard for Q versions).
- Condensation control through over pressure fans (only for T versions).
- Power factor correction capacitor (Cos>0,94).
- Forced power consumption limit.
- Forced noise limit.
- Energy parameters measurement device.
- Energy efficiency optimization.
- Soft starter.
- Compressor box with acoustical insulation and acoustical insulation of cooling circuit.
- Acoustical insulator for the compressor.
- Suction and compression valves of cooling circuit.
- Refrigerant leakage detector.
- High and low pressure gauges for the refrigerant circuit.
- Double safety valves.
- Metal filters or coil protection grills.
- Lower section protection grills.
- Copper pipe/coated aluminium finned or copper pipe/copper finned coils.
- Digital input for double set point.
- Set point shift (4-20 mA analogue signal).
- Evaporator anti-freezing heater, electrical panel, accumulation tank and electric pumps and heat exchangers for heat recovery if applicable.
- Interfaces for serial communication with other devices.
- Spring anti-vibration mouths.
SEPARATELY SUPPLIED ACCESSORIES
- Remote controller with display.
- Thermostat with display.
- Control devices for monitoring and remote management of the device.
- Sequencer for integrated management of multiple chillers.
- Water filter.
- Rubber anti-vibration mouths.
- Thermostat with display.
- Remote controller with display.
- Interfaces for serial communication with other devices.
- RS485/USB series convertor.
- Sequencer for integrated management of multiple chillers.