Multi-purpose units with TER up to 8,25
Extended operating limits
Units for systems with 2, 4 and 6 pipes
SEER up to 5.29 with FIEC accessory (EC fans) and SCOP up to 3.89

 

R454B Eco-Friendly Gas
Class A Polyvalent Device
Special Energy Efficient Solutions for Commercial Building and Residences
Wide and Smart Options

 

Quick info

Description

Technical Features
Options
Documents
Let's Call You

STRUCTURAL FEATURES

Compressor: Hermetic scroll compressor with thermal protection and crankcase heater.
High efficiency at partial capacities through 4-6 capacity controls.
Evaporator: Plate evaporator with differential pressure switch, built-in Victaulic connection and stainless steel polyurethane insulation.
Condenser: Copper pipe/aluminium finned condenser.
Fan: Axial fan with built-in thermal protection and protective grill.
(for T version; EC fans are standard for Q versions).
Control: Microprocessor control with the feature of Adaptive Function Plus.
Carcass Structure: Powder polyester painted galvanized steel structure.

STANDARD FEATURES

• Circuit disconnecting switches of fan and compressor, anti-freezing heater for the heat exchanger.
• High and low pressure gauge.
• Electronic expansion valve.
• Time-card.

VERSIONS

T - High efficiency version, EXP systems unit (TXAETU).
Q - Super silenced version, EXP systems unit (TXAEQU).

FACTORY FITTED ACCESSORIES

  • Shell & tube evaporators.
  • Single or double pump. 1 main and 1 backup applications in double pump options.
  • Standard and high pressure versions of pumps are optional.
  • Tank and Pump Unit: Accumulation tank up to 700-1000 litres depending on the model, with expansion tank, manual air relief valve, safety valve and water side pressure gauge. Low or high pressure versions of those pumps are available.
  • Partial heat recovery option (Desuperheater).
  • FI-15 kit: operation at -15 C outdoor air temperature (Condensation control) (through fans with EC motor) (standard for Q versions).
  • Condensation control through over pressure fans (only for T versions).
  • Power factor correction capacitor (Cos􀀁>0,94).
  • Forced power consumption limit.
  • Forced noise limit.
  • Energy parameters measurement device.
  • Energy efficiency optimization.
  • Soft starter.
  • Compressor box with acoustical insulation and acoustical insulation of cooling circuit.
  • Acoustical insulator for the compressor.
  • Suction and compression valves of cooling circuit.
  • Refrigerant leakage detector.
  • High and low pressure gauges for the refrigerant circuit.
  • Double safety valves.
  • Metal filters or coil protection grills.
  • Lower section protection grills.
  • Copper pipe/coated aluminium finned or copper pipe/copper finned coils.
  • Digital input for double set point.
  • Set point shift (4-20 mA analogue signal).
  • Evaporator anti-freezing heater, electrical panel, accumulation tank and electric pumps and heat exchangers for heat recovery if applicable.
  • Interfaces for serial communication with other devices.
  • Spring anti-vibration mouths.

SEPARATELY SUPPLIED ACCESSORIES

  • Remote controller with display.
  • Thermostat with display.
  • Control devices for monitoring and remote management of the device.
  • Sequencer for integrated management of multiple chillers.
  • Water filter.
  • Rubber anti-vibration mouths.
  • Thermostat with display.
  • Remote controller with display.
  • Interfaces for serial communication with other devices.
  • RS485/USB series convertor.
  • Sequencer for integrated management of multiple chillers.