Description
STRUCTURAL FEATURES
Compressor: Hermetic scroll compressor with thermal protection and crankcase heater.
High efficiency at partial capacities through 4-5-6 capacity controls.
Evaporator: Plate evaporator with differential pressure switch, built-in Victaulic connection and stainless steel polyurethane insulation.
Condenser: Condenser with micro channels (TCAEY) or copper pipe/aluminium fin.
Fan: Axial fan with built-in thermal protection and accident protection grill.
Control: Microprocessor control with the feature of Adaptive Function Plus.
Structure: Powder polyester painted galvanized steel structure
STANDARD FEATURES
•Circuit disconnecting switches of fan and compressor.
•High and low pressure gauge.
•Master/slave control up to parallel 4 units.
•Time-card.
VERSIONS
T - High efficiency version, only cooling (TCAETY) – heat pump unit (THAETY).
Q - Super silenced version, only cooling (TCAEQY).
FACTORY FITTED ACCESSORIES
• Shell & tube evaporator.
• Single or double pump. 1 main and 1 backup applications in double pump options.
• Standard and high pressure versions of pumps are optional.
• TANK and PUMP UNIT: Accumulation tank up to 700-1000 litres depending on the model, with expansion tank, manual air relief valve, safety valve and water side pressure gauge. Low or high pressure versions of those pumps are available.
• Pump control with variable flow (VPF: Variable Primary Flow).
• Partial heat recovery option (Desuperheater).
• Full (100%) heat recovery option.
• FI-10 kit: operation at -10 C outdoor air temperature (Condensation control) (standard for Q versions),
• FI-15 kit: operation at -15 C outdoor air temperature (Condensation control) (through fans with EC motor) (standard for Q versions).
• Condensation control through over pressure fans.
• Power factor correction capacitor (Cosɸ>0,94).
• Forced power consumption limit.
• Forced noise limit.
• Energy parameters measurement device.
• Energy efficiency optimization.
• Soft starter.
• Compressor box with acoustic insulation or acoustical insulation for the compressor box and cooling circuit (THAEY)
• Acoustic insulator of the compressor,
• Suction and compression valves of cooling circuit.
• Refrigerant leakage detector.
• High and low pressure gauges for the refrigerant circuit.
• Double safety valves.
• Digital input for double set point.
• Metal filters (THAEY) or protecting grills of condenser coil
• Epoxy coated micro channels condenser (TCAEY).
• Copper/copper or copper/aluminium coated condenser (THAEY).
• Minimum/maximum power supply control.
• Digital input for double set point.
• Set point shift (4-20 mA analogue signal).
• Evaporator anti-freezing heater, electrical panel, accumulation tank, electric pumps and heat exchangers for heat recovery if applicable.
• Water production in low temperatures.
• Interfaces for serial communication with other devices.
• Anti-vibration mouths.
SEPARATELY SUPPLIED ACCESSORIES
• Remote controller with display.
• Thermostat with display.
• Control devices for monitoring and remote management of the device.
Sequencer for integrated management of multiple chillers.