Compact and High Efficiency Series with R410a Refrigerant Gas
4-5-6 Staged Capacity Control,
Easy Installation with Tank & Pump Accessories
2 Piped + Heat Recovery (RC 100) Option
Built-in Master/Slave Control

 

Eurovent Certified High Performance
High Energy Efficiency and Comfort in All Seasons
Wide and Smart Options
Increased Outdoor Air Operating Limits
Special Energy Efficient Solutions for Commercial Building

 

Quick info

Description

Technical Features
Options
Documents
Let's Call You

STRUCTURAL FEATURES

Compressor: Hermetic scroll compressor with thermal protection and crankcase heater.
High efficiency at partial capacities through 4-5-6 capacity controls.
Evaporator: Plate evaporator with differential pressure switch, built-in Victaulic connection and stainless steel polyurethane insulation.
Condenser: Condenser with micro channels (TCAEY) or copper pipe/aluminium fin.
Fan: Axial fan with built-in thermal protection and protective grill.
Control: Microprocessor control with the feature of Adaptive Function Plus.
Structure: Powder polyester painted galvanized steel structure.

STANDARD FEATURES

•Circuit disconnecting switches of fan and compressor.
•High and low pressure gauge.
•Master/slave control up to parallel 4 units.
•Time-card.

VERSIONS

• B - Standard version, Only cooling (TCAEBY) – heat pump unit (THAEBY).
• S - Silenced version, Only cooling (TCAESY) – heat pump unit (THAESY).

FACTORY FITTED ACCESSORIES

• Shell & tube evaporator.
• Single or double pump. 1 main and 1 backup applications in double pump options.
• Standard and high pressure versions of pumps are optional.
• Tank and Pump Unit: Accumulation tank up to 700-1000 litres depending on the model, with expansion tank, manual air relief valve, safety valve and water side pressure gauge. Low or high pressure versions of those pumps are available.
• Pump control with variable flow (VPF: Variable Primary Flow).
• Partial heat recovery option (Desuperheater).
• Full (100%) heat recovery option.
• FI-10 kit: operation at -10 C outdoor air temperature (Condensation control) (standard for S versions).
• FI-15 kit: operation at -15 C outdoor air temperature (Condensation control) (through fans with EC motor). (standard for Q versions).
• Condensation control through over pressure fans.
• Power factor correction capacitor (Cosɸ>0,94).
• Forced power consumption limit.
• Forced noise limit.
• Energy parameters measurement device.
• Energy efficiency optimization.
• Soft starter.
• Compressor box with acoustic insulation or acoustical insulation for the compressor box and cooling circuit (THAEY).
• Acoustical insulator for the compressor.
• Suction and compression valves of cooling circuit.
• Refrigerant leakage detector.
• High and low pressure gauges for the refrigerant circuit.
• Double safety valves.
• Digital input for double set point.
• Metal filters (THAEY) or protecting grills of condenser coil.
• Epoxy coated micro channels condenser (TCAEY).
• Copper/copper or copper/aluminium coated condenser (THAEY).
• Minimum/maximum power supply control.
• Digital input for double set point.
• Set point shift (4-20 mA analogue signal).
• Evaporator anti-freezing heater, electrical panel, accumulation tank, electric pumps and heat exchangers for heat recovery, if any applicable.
• Water production in low temperatures.
• Interfaces for serial communication with other devices.
• Anti-vibration mouths.

SEPARATELY SUPPLIED ACCESSORIES

• Remote controller with display.
• Thermostat with display.
• Control devices for monitoring and remote management of the device.
• Sequencer for integrated management of multiple chillers.